  specifications subject to change without notice. dimensions (mm). see appendix a for recommended power cord. see pdi full line catalog for detailed specifications on power cords. mechanical dimensions (unit: mm) case a case b case c mechanical dimensions features the hgn-375(a, b, c) series offers filters in three different package styles - flange mount (sides), flange mount (top/bottom), & snap-in type. this cost effective series offers more component options with better performance in curbing common and differential mode noise. these filters are equipped with iec connector, fuse holder for one or two 5 x 20 mm fuses, 2 pole on/off switch and fully enclosed metal housing. these filters are also available for medical equipment with low leakage current and have been designed to bring variousmedical equipments into compliance with en55011 and fcc part 15j, class b conducted emissions limits. applications computer & networking equipment, measuring & control equipment, data processing equipment, laboratory instruments, switching power supplies, other electronic equipment. technical data ? rated voltage: 125/250vac ? rated current: 1a, 2a, 3a, 4a, 6a, 10a ? power line frequency: 50/60hz ? max. leakage current each line to ground: @ 115vac 60hz: 0.5ma, max @ 250vac 50hz: 1.0ma, max @ 125vac 60hz: 2 a*, max @ 250vac 50hz: 5 a*, max ? hipot rating (one minute) line to ground: 2250vdcline to line: 1450vdc ? temperature range: -25c to +85c * medical application (unit: mm) fused with on/off switch, iec 60320 power inlet socket with fuse/s (5x20mm) hgn-375(a, b, c) 29 6.3 typ. 72.0 60.8 r2.5 typ. recommended panel cutout (mount from front) 29.3 2x 3.5 +0.5 +0.5 +0.1 59.8 48.7 (3.5) 82 72 2x 3.3 use only with a 250v fuse employer uniquement avec un fusible de 250v 29 6.3 typ. r2.5 typ. 29.3 61.4 +0.5 +0.3 suggested panel cutout (mounting from front) thickness of panel is from 1.00mm to 1.6mm 59.8 (56.2) 48.7 (3.5) (61.3) 28 65 32 59.5 use only with a 250v fuse employer uniquement avec un fusible de 250v 49.83 32.45 65.4 40 + - - 0.2 o use only with a 250v fuse employer uniqement avec un fusible de 250v 60.0 49.37 3.5 55.04 60.71 28.5 6.30 typ . 4x r0.5 2x m3 40.0 + - - 0.2 61.5 29.5 81 145 algonquin parkway, whippany, nj 07981 ? 973-560-0019 ? fax: 973-560-0076 e-mail: filtersales@powerdynamics.com ? www.powerdynamics.com
hgn-375(a, b, c) series example & ordering code hgn-375 current rating (a): = 01 = 02= 03 = 04 = 06 = 10** terminal: = q = s= w options: = 0 = 5= 6 = 7 @ = 8 @ = 9 @ quick connect solderwire - - no bleeder resistor & no ground choke bleeder resistor (1/4 w, 1m) bleeder resistor (1/2 w, 1m) bleeder resistor (1/4 w, 1m) & ground choke bleeder resistor (1/2 w, 1m) & ground choke ground choke (400h) component locations: = 1 = 2 b = 1m = 2m b standard type standard type; additional c(x) behind l without c(y); c(x) only without c(y); additional c(x) behind l 6.3/0.25 4.0/0.187 ul 1015, 18awg stranded, 4? 01 q 1 5 1 schematics medical schematics attenuation code table: capacitor c(x) 1a (mh) 2a (mh) 3a (mh) 4a (mh) 6a (mh) 10a (mh) 0.1f 6.5 3.8 2.5 1.6 0.8 0.2 0.1f 3.7 2.7 1.8 1.3 0.8 0.3 0.22f 7.5 5.5 2.5 2.0 0.8 0.4 0.22f 10.5 6.5 2.5 2.7 1.05 0.4 medical applications, select attenuation code with corresponding component values from the table. non-medical applications, select attenuation code with corresponding component values from the table. capacitor c(x) capacitor c(y) 1a (mh) 2a (mh) 3a (mh) 4a (mh) 6a (mh) 10a (mh) 0.1f 2200pf 6.5 3.8 2.5 1.6 0.8 0.2 0.1f 3300pf 3.7 2.7 1.8 1.3 0.8 0.3 0.22f 2200pf 7.5 5.5 2.5 2.0 0.8 0.4 0.22f 3300pf 10.5 6.5 2.5 2.7 1.05 0.4 = a = b= c = d 1 2 1m 2m = m1 = m2 = m3= m4 8.0 3.0 -3.6l 6.6 2.0 -3.0l a fuse & switch options: = 1 = 2= 3 = 4 = 5 = 6 black, non-illuminated switch, 1 fuse (5x20mm) black, non-illuminated switch, 2 fuse (5x20mm) red illuminated switch, 1 fuse (5x20mm) red illuminated switch, 2 fuse (5x20mm) green illuminated switch, 1 fuse (5x20mm) green illuminated switch, 2 fuse (5x20mm) c x g load l mh l mh cy l l' n' g' lg cy r fuse l n line fuse c x g load l mh l mh l l' n' lg r fuse l n line fuse g' c x g l mh l mh l r fuse l n line fuse load l' n' g' cy cy c x c x l mh l mh l r fuse l n line fuse load l' n' c x g' g b contact pdi for attenuation numbers **ul and cul approved to 10a; vde approved to 6.3a @ not available for schematic 2 & 2m options: a case code: = a = b= c flange mount, sides flange mount, top/bottom snap-in 82 145 algonquin parkway, whippany, nj 07981 ? 973-560-0019 ? fax: 973-560-0076 e-mail: filtersales@powerdynamics.com ? www.powerdynamics.com
hgn-375(a, b, c) series attenuation tables comm. mode(l-g) in mhz diff. mode(l-l) in mhz .15 .5 1 5 10 30 .15 .5 1 5 10 30 35 38 40 32 20 24 8 25 37 71 62 12 30 34 36 31 18 22 8 23 34 68 64 14 27 34 36 29 23 22 8 19 27 58 65 15 22 27 28 29 26 13 8 18 26 43 51 31 20 25 26 27 25 32 8 18 25 29 38 31 9 13 19 19 17 13 7 17 23 39 47 27 28 35 37 28 22 24 8 20 29 61 48 15 25 33 58 51 56 41 8 20 30 57 47 13 11 16 18 18 16 12 8 18 24 47 36 24 19 23 24 27 27 21 8 19 27 47 45 30 11 16 18 18 16 12 8 18 24 47 36 24 37 45 41 22 30 19 17 35 47 57 44 34 31 35 37 31 37 15 16 34 48 57 54 18 25 29 30 26 19 12 15 28 38 52 47 19 24 27 28 30 27 22 14 26 37 44 45 23 19 24 25 25 23 17 15 26 33 50 44 27 14 16 18 20 20 15 14 26 34 37 35 26 17 36 49 65 47 23 38 42 42 25 43 16 35 38 40 33 20 24 16 33 45 66 53 14 26 30 31 27 19 14 14 27 37 60 46 20 19 24 25 25 24 17 14 25 33 45 42 29 attenuation code a b c d attenuation code m1 m2 m3 m4 current rating 1a 2a3a 4a 6a 10a 1a 2a3a 4a 10a 1a 2a3a 4a 6a 10a 1a 2a4a 6a current rating 1a 2a3a 4a 6a 10a 1a 2a3a 4a 6a 10a 1a 2a3a 4a 6a 10a 1a 2a3a 4a 6a 10a comm. mode(l-g) in mhz diff. mode(l-l) in mhz .15 .5 1 5 10 30 .15 .5 1 5 10 30 34 38 40 32 26 11 8 25 37 71 62 12 29 32 55 48 49 51 8 23 34 68 64 14 28 36 39 45 48 39 8 19 27 58 65 15 22 27 30 48 54 47 8 19 28 66 72 34 18 24 28 44 50 47 8 18 26 43 51 31 8 14 18 33 41 39 8 18 25 29 38 31 29 33 47 53 57 41 8 23 35 73 58 14 28 37 44 52 56 41 8 19 27 74 59 17 25 33 46 53 57 44 8 19 29 63 62 13 19 24 27 43 53 38 8 18 25 57 60 32 19 29 36 49 55 46 8 18 23 50 54 24 11 19 24 41 53 36 8 18 24 51 46 25 37 44 52 47 48 49 17 35 48 65 57 36 31 34 48 50 52 50 16 33 48 63 62 17 25 30 34 45 47 39 15 27 37 59 57 21 27 28 33 50 56 48 14 26 35 51 57 24 19 25 30 43 51 44 15 25 32 60 59 29 14 19 24 41 54 42 14 25 33 45 56 31 36 54 53 45 32 40 26 60 84 49 36 17 35 42 50 51 57 59 15 32 45 70 71 14 25 31 37 48 52 37 15 27 37 60 56 23 26 32 41 49 51 45 14 26 36 64 57 23 19 27 32 47 56 45 14 25 31 56 59 31 14 18 22 38 49 41 17 42 64 58 49 29 v this table applies to schematic 1 only. visit our website or contact pdi for other schematic attenuation numbers. g this table applies to schematic 1m only. visit our website or contact pdi for other schematic attenuation numbers. medical applications non-medical applications v g insertion loss in db (50 ohm circuit) insertion loss in db (50 ohm circuit) 83 145 algonquin parkway, whippany, nj 07981 ? 973-560-0019 ? fax: 973-560-0076 e-mail: filtersales@powerdynamics.com ? www.powerdynamics.com


▲Up To Search▲   

 
Price & Availability of HGN-375C01S-30-1M3

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X